qiao@hvtest.cc15871365102
  • UHV-655 Transformer Oil Open Cup Flash Point Pensky Martens Analyzer

    Ang UHV-655 Awtomatikong open cup flash point at ignite point tester ay pangunahing ginagamit upang sukatin ang halaga ng bukas na flash point at halaga ng ignition point ng mga produktong petrolyo. Ito ay isang espesyal na instrumento na pumapalit sa mga imported na produkto sa mga industriya tulad ng petrolyo, kapangyarihan, kemikal, at inspeksyon ng kalakal.

    Mga Detalye ng Produkto ng UHV-655 Transformer Oil Open Cup Flash Point Pensky Martens Analyzer


    Product Introduction

    The fully automatic open flash point tester is designed for measuring the open flash point and ignition point of petroleum products. Utilizing an electric ignition method, the instrument operates without the need for any combustible gas and fully complies with the standards of ASTM D92 (GB/T 3536-2008) and GB 267-88.

    Equipped with an ARM-based high-performance microprocessor, electrically erasable memory capable of storing thousands of data entries, a color LCD touchscreen, and PID self-tuning technology, the instrument integrates state-of-the-art advancements.

    With performance and functionality at the forefront of both domestic and international standards, this open flash point tester serves as a premium domestic alternative to imported instruments, widely applied in industries such as petroleum, power, chemicals, and commodity inspection.


    Mga Tampok ng Produkto

    1. Comprehensive Functionality: Capable of detecting both flash point and ignition point, with integrated test result printing. The built-in clock chip automatically displays the current date and time, and retains settings during power outages.

    2. High Measurement Accuracy: Temperature control error is within ±1.5°C, with a resolution of 0.1°C.

    3. Excellent Repeatability: Under testing conditions compliant with GB/T 3536 (ASTM D92) or GB/T 267-88, repeated testing of the same sample yields a flash point variation of ≤4°C.

    4. High Level of Automation: Automatically completes the entire testing process, including cooling, with intuitive on-screen prompts to guide operation.


    Automatic Open Cup Flash Point Tester 1Automatic Open Cup Flash Point Tester 2Automatic Open Cup Flash Point Tester 3


    Mga Teknikal na Parameter

    Hanay ng pagsukatRoom temperature~400 ℃
    Uri ng pagtuklasOpen flash point or ignition point
    Pagtuklas ng temperaturaplatinum
    Katumpakan±1℃
    Pag-uulitconform to GB3536-2008(ASTM D92)、GB/T 267-88
    PagpapakitaColor LCD display
    Imbakan ng impormasyonCan store 1000 measurement results
    Paraan ng pag-aapoyelectric ignition
    Paraan ng paglamigForced air cooling
    PrinterDot matrix thermal printer
    Self inspection functionLifting rod, sweeping rod, printing, etc
    kapangyarihan≤600VA
    Using the power supplyAC 220V ± 11V, frequency 50Hz ± 2.5Hz
    Temperatura sa paligid10~35℃
    Ambient humidity≤90%
    TimbangAbout 17kg


    Working principle

    The open flash point tester records the low temperature of liquid vapor scintillation by heating the liquid to be tested and conducting a fire source test at a specified temperature. Unlike the closed flash point tester, the open flash point tester uses an open container with a larger contact surface between air and liquid, making it suitable for detecting certain special liquids. The process of open flash point testing is slightly simpler than closed flash point testing, but the results obtained are often more practical, especially for volatile liquids.


    Automatic Open Cup Flash Point Tester 4
    Automatic Open Cup Flash Point Tester 5Automatic Open Cup Flash Point Tester 6


    Application Scenarios

    1. Petrochemical industry

    Petroleum products: crude oil, gasoline, diesel, lubricating oil, fuel oil, paraffin, etc., used to evaluate the volatility, safety, and storage and transportation regulations of oil products (such as the flash point of diesel is a key indicator to determine its flammability).

    Chemical raw materials: organic chemical raw materials such as solvent oil, benzene, alcohols, esters, etc., and their fire risks during production and transportation are tested.

    2. Energy and power industry

    Insulating oil: Transformer oil, cable oil, etc. The flash point is an important indicator for monitoring the quality of insulating oil. A low flash point may indicate oil aging or the presence of low boiling impurities, affecting equipment safety.

    Fuel oil: Heavy oil, residual oil, etc. used in power plants are tested for flash point to ensure the safe operation of the combustion system.

    3. Coatings and Polymer Materials

    Coatings and inks: Flash point testing of solvents (such as xylene and ethyl acetate) in solvent based coatings and printing inks is related to the explosion-proof level design and transportation packaging requirements of the production workshop.

    Polymer raw materials: plasticizers, resin monomers (such as vinyl chloride, styrene), used to evaluate the fire hazards during raw material storage and processing.

    4. Pharmaceutical and food industries

    Pharmaceutical solvents: Ethanol, acetone and other pharmaceutical solvents must comply with the pharmacopoeia's flash point regulations to ensure the safety of the production process.

    Food additives: Flash point testing of some edible oils and fats (such as vegetable oils), used for quality control (although not directly consumed, risks need to be avoided during processing).

    5. Research and quality inspection institutions

    Material research and development: Performance testing of new chemical materials and fuels, providing data support for formula optimization.

    Quality supervision: Third party testing agencies conduct compliance inspections on imported and exported oil and chemical products.


    Frequently Asked Questions

    1. What is a fully automatic open flash point tester?

    The fully automatic open flash point tester is a laboratory equipment used to determine the open flash point and ignition point of petroleum products and other flammable liquids. The instrument adopts automatic heating, automatic ignition, automatic detection of flash point, and automatic display of test results, which can effectively improve testing efficiency and accuracy.

    2.  What is the difference between open flash point and closed flash point?

    The open flash point test is conducted in an open environment and is more suitable for high flash point petroleum products, such as lubricating oil, transformer oil, heavy oil, etc; The closed flash point test is suitable for low flash point, volatile liquids such as gasoline, diesel, and solvents, so the two methods are applicable to different samples.

    3. How long does a test take?

    Depending on the flash point of the sample, it generally takes 10-20 minutes to complete a test, and the testing time for high flash point samples will increase accordingly.

    4. Will the test results be affected by the ambient air pressure?

    meeting. Modern fully automatic open flash point testers usually have built-in pressure sensors that can automatically correct atmospheric pressure, improving the accuracy and consistency of test results.

    5. Does it support both Chinese and English operating interfaces?

    Support. Most export models offer bilingual interfaces in Chinese and English, and other language versions can also be customized according to customer needs.