qiao@hvtest.cc15871365102

    < >

    UHV-1200 6 Phase Relay Tester Secondary Injection Test

    UHV-1200 6 Phase Relay Tester Secondary Injection Test is flexible combination of voltage and current output up to 6 phase voltage and 6 phase current, can be any combination to achieve conventional 4 phase voltage, 3 phase current type, 6 phase voltage type, 6 phase current type, and 12 phase output mode, not only compatible with the traditional various test methods, but also convenient for three-phase transformer differential test and plant power quick cutting and ready self-injection test

    Product Details of UHV-1200 6 Phase Relay Tester Secondary Injection Test


    six phase relay tester


     Parameter

    Type

    -

    Current channel number

    Standard six phase

    Voltage channel number

    Standard six phase

    AC current output range

    30A / phase or180A (six phase parallel)

    DC current output range

    10A DC /phase

    AC voltage output range

    120V AC /phase

    DC voltage output range

    160V DC / phase

     

     Nominal parameter

    AC current output

    Thevirtualvalue of each phase output when six phase current output

    030A

    output precision

    0.1 grade

    Thevirtualvalue of each phase output when three phase current output

    060A

    Thevirtualvalue of six phase parallel current output

    0180A

    The allowedvirtual value when the phase current work long time

    10A

    The maximum output power of phase current

    450VA

     

    The maximum output power when six phase parallel current output

    1000VA

     

    The allowedworkingtime when six phase parallel current maximum output

    10s

    Frequency rangefundamental wave

    01000Hz

    Harmonic order

    020

     

    DC current output

    Current output

    0±10A /phase

    The maximum load volatage output

    0.2 grade

    ACvoltageoutput

    20V

    Thevirtualvalue of phasevoltageoutput

    0120

     

    Voutput precision

    0.1 grade

     

    Thevirtualvalue of line voltageoutput

    0240V

    Theoutput power of phase voltage/ line voltage

    80VA / 100VA

     

    Frequency rangefundamental wave

    01000Hz

    Harmonic order

    020

    DCvoltageoutput

    The output amplitude of phase voltage

    0±160V

    output precision

    0.2 grade

    The output amplitude of line voltage

    0±320V

    Theoutput power of phase voltage/ line voltage

    70VA / 140VA

    Input and output

     

    8channelsinput

     

    Free contact

    120mA24V

    Electric potential contacts

    “0”0  +6V “1”+11 V +250 V

    4channelsoutput

    Electric potential contacts

    DC220 V0.2 AAC220 V0.5 A

     

    Time measurment range

     

    0.1ms 9999s    measurement accuracy0.1ms

     

     

     

    Nicknamesix phase relay testerrelay test kitsecondary injection testRelay Tester





    Feature:

     

     Flexible combination of voltage and current output

    Six phasevoltage and sixphase current can be output, which has made it is possiable to be any combition, such as theoutput mode of thecombination of conventional four phase current and three-phase current, six phasevoltage mode, six phasecurrent mode and 12 phase output mode. It not only can be compatible with the traditional way of various tests,but alsocan conveniently carry out differential test ofthree-phase transformer.

     Operation mode

    The device is directly connected with a computer or a desktop computer, which is convenient and efficient and stable performance.

     A new hi-filinearpoweramplifier 

    The output port hasalways insisted onusing themodular linear power amplifierinstead of theswitching power amplifier, which hasthe high fidelity andhigh reliabilityfunction andexcellent performance.High-midfrequency will not be produced to disturbthe test, alsoensurethesmoothing accuracyofwaveformproduced by the whole course ofthe high current to the tiny current is excellent.

     High performanceMainframe

    Theoutput part adopts DSP control,which hasfast operation, real-time digital signal processing capability, wide bandwidth andhigh resolution D/A conversion control. The output waveform has the features ofhigh precision, small distortion and good linearity.With using a large number of advanced technology and precision components and materials andthe structure of professional design, the device hasthe features ofsmall volume, light weight, full function, easy to carry, boot can work, flow test is very convenient.

     Powerful software function

    Itcan complete all kinds of high automatic validation work which is large and complex.It canalsoconveniently test and scan protection setting,playback offault, real-time store test data, display vector, online print report and so on. Besides, six-phase current can facilitate the testofthree-phase differential protection.

     Independent DC power output

    An 110V and 220VadjustableDC power is designed tosupply output.

     Complete interface

    The device with USB communication portcancommunicate with the computer and other external devices.

     Perfect self-protection function

    Withreasonable design of the heat dissipation structureandthe reliable and perfect hardware protection measures,it has the power soft start function andthe software of the faultself-diagnosis and the output latch function.










    You Might Also Like

    • Have Any Questions!

      DON'T HESITATE TO CONTACT US ANY TIME
      Contact us
    • Visit Us

      Building 6, Optics Valley Optical-Mechanical Industrial Park, 84 Gaoxin 5 Road,
      East Lake New Technology Development Zone, Wuhan City, Hubei Province, China

    • Email Us

      qiao@hvtest.cc

    • Call Us

      +86-15871365102