qiao@hvtest.cc15871365102
  • UHV-1200 6 Phase Relay Tester Secondary Injection Test

    Ang UHV-1200 6 Phase Relay Tester Secondary Injection Test ay nababaluktot na kumbinasyon ng boltahe at kasalukuyang output hanggang sa 6 na phase na boltahe at 6 na yugto ng kasalukuyang, ay maaaring maging anumang kumbinasyon upang makamit ang maginoo na 4 phase na boltahe, 3 phase na uri ng kasalukuyang, 6 na bahagi ng boltahe na uri, 6 kasalukuyang uri ng phase, at 12 phase output mode, hindi lamang tugma sa tradisyonal na iba't ibang mga pamamaraan ng pagsubok, ngunit maginhawa din para sa three-phase transformer differential test at plant power quick cutting at ready self-injection test

    Mga Detalye ng Produkto ng UHV-1200 6 Phase Relay Tester Secondary Injection Test


    Product Introduction

    The UHV-1200 Microcomputer Relay Protection Tester features a highly flexible combination of voltage and current outputs, supporting up to 6-phase voltage and 6-phase current channels. It allows users to configure various

    output modes, such as the conventional 4-phase voltage and 3-phase current setup, 6-phase voltage output, or combined 6-phase and 12-phase output modes. This design ensures compatibility with traditional testing

    methods and also facilitates advanced applications such as differential testing of three-phase transformers, fast bus transfer tests, and backup auto-reclosing verification.

    The high-performance main unit employs DSP control in its output section, providing fast processing speeds, strong real-time digital signal processing capabilities, wide transmission bandwidth, and high-resolution D/A

    conversion. This ensures high waveform precision, minimal distortion, and excellent linearity in output signals.

    Through the application of advanced technologies, precision components, and materials—along with a professional structural design—the device achieves a compact and lightweight form factor without compromising

    functionality. It is fully portable, easy to set up, and convenient for on-site or mobile testing applications.


    Mga Tampok ng Produkto

    1、Flexible Output Configuration

    Supports up to 6-phase voltage and 6-phase current outputs, configurable in various modes for compatibility with conventional testing, differential protection, and advanced grid simulations.

    2、High-Fidelity Power Amplifier

    Utilizes modular linear power amplifiers to ensure clean, stable waveforms without medium/high-frequency interference.

    3、High-Performance DSP Control

    DSP-based output with fast processing, high-resolution D/A conversion, and excellent waveform accuracy.

    4、Compact and Portable Design

    Lightweight, integrated structure with full functionality for easy transport and field testing.

    5、Comprehensive Software Suite

    Enables automated testing, fault simulation, data storage, vector display, and report generation.

    6、Independent DC Power Output

    Includes 110V/220V adjustable DC power supply for auxiliary testing.

    7、Extensive Connectivity

    Features USB and other communication interfaces for PC connection and external device integration.

    8、Built-in Protection Mechanisms

    Incorporates thermal management, soft-start, fault diagnostics, and output lockout for safe operation.

    9、Laptop-Compatible Operation

    Can be operated with an external laptop using the same intuitive software interface.


    6 Phase Relay Tester 1
    6 Phase Relay Tester 2


    Mga Parameter ng Produkto

    Argument

    Kasalukuyang channel numberStandard 6 phase
    Numero ng channel ng boltaheStandard 6 phase
    Ac current output range30A/phase or 180A (six parallel)
    Dc current output range10A DC/phase
    Ac voltage output range120V AC/phase
    Dc voltage output range160V DC/phase

    Kasalukuyang output ng AC

    6 phase current output per phase(effective value)0~30A output precision 0.2
    3 phase current output per phase(effective value)0~60A
    6 phase parallel current output(RMS)0~180A
    Phase current long-term allowable working value(RMS)10A
    Maximum output power of phase current450VA
    T6 phase parallel current maximum output power1000VA
    6 Allowable working time for maximum output of phase parallel current10s
    Frequency range(fundamental)0~1000Hz
    Harmonic frequency0 to 20 times

    DC kasalukuyang output

    Kasalukuyang output0~±10A/phase output accuracy 0.5 level
    Maximum output load voltage20V

    Output ng boltahe ng AC

    Phase voltage output(RMS)0~120V output precision 0.2
    Line voltage output(RMS)0~240V
    Phase voltage/line voltage output work80VA/100VA
    Saklaw ng dalas (pangunahing)0~1000Hz
    Harmonic frequency0 to 20 times

    Output ng boltahe ng DC

    Phase voltage output amplitude0~±160V output accuracy 0.5
    Line voltage output amplitude0~±320V
    Phase voltage/line voltage output power70VA/140VA

    Switching value

    8 switch inputsNull contact 1~20mA, 24V
    0 Potential contact access "0" : 0~+6V; 1: +11V to +250V
    4 pairs of switching outputDC:220V/0.2A; AC:220V/0.5A

    Saklaw ng pagsukat ng oras

    Saklaw ng pagsukat ng oras0.1ms~9999s
    Katumpakan ng pagsukat0<0.1mS

    6 Phase Relay Tester 3
    6 Phase Relay Tester 4


    Core functionality

    1. Multi channel analog output: capable of outputting AC, DC current, voltage, and phase signals, simulating various power system operating states and typical fault situations, such as overcurrent, undervoltage, differential, and distance protection.

    2. Action time measurement: Accurately record the time from receiving the signal to completing the action of the relay protection device, ensuring that it meets the standard requirements, thereby ensuring rapid fault removal.

    3. Action value verification: It can test whether the action current and voltage values set by the protection device are consistent with the actual action values, and verify the accuracy and sensitivity of the device.

    4. Logic function testing: supports simulation and verification of complex protection logic, such as multi-stage overcurrent protection, linkage tripping, and automatic reclosing logic, to ensure that the protection strategy is effective in actual operation.

    5. Data recording and analysis: Modern testers usually have data storage and intelligent analysis functions, which can generate test reports for historical data comparison, trend analysis, and operation and maintenance management.


    Application scenarios:

    1. Acceptance of newly put into operation device: After the installation of the protective device, comprehensively test its action values, time limits, and logical functions to ensure compliance with the requirements of the fixed value sheet.

    2. Regular inspection: Regularly verify the protection (such as differential, distance, overcurrent protection) during operation according to regulations to ensure its reliability.

    3. Post fault analysis: After a system malfunction, simulate the fault quantity to test the protective action behavior and determine whether there is refusal, misoperation, or characteristic drift.

    4. Protection system transmission test: Apply simulated fault current and voltage to verify the correctness of the entire circuit from relay sensing fault to circuit breaker tripping.


    Product Frequently Asked Questions

    1. What protection devices can the relay protection tester test? It covers almost all common types of protection, including line protection, transformer protection, busbar protection, generator protection, motor protection, differential protection, distance protection, overcurrent protection, and low cycle load shedding devices.

    2. Why doesn't the protective device work? In most cases, it is related to wiring errors, incorrect setting of settings, improper selection of test items, or abnormal wiring of input and output circuits.

    3. How to deal with the inability to output test voltage? Firstly, confirm the software parameter settings. Secondly, check the fuse, output switch, and voltage circuit wiring.

    4. Does the relay protection tester need to be grounded? The answer is that it must be grounded. Good grounding is not only related to the accuracy of test results, but also to the safety of test personnel.

    5. Why does the repetition of action time decrease? Common causes include fluctuations in auxiliary power supply, poor contact of contacts, internal faults in protective devices, and environmental electromagnetic interference.

    6. What are the most common problems during distance protection testing? Impedance calculation errors and polarity reversal are the two most common problems on site.

    7. How to choose between six phase equipment and three-phase equipment? For units with more tests on line protection, transformer protection, and differential protection, six phase equipment can significantly improve work efficiency.

    8. How to choose a reliable manufacturer of relay protection tester? Attention should be paid to product accuracy, software functionality, after-sales service, and manufacturer's technical strength. For example, Wuhan UHV Power Technology Co., Ltd.










    Baka Magustuhan Mo rin

    • Bisitahin mo kami

      Building 6, Optical Valley Optical-Mechanical Industrial Park, 84 Gaoxin 5 Road,
      East Lake New Technology Development Zone, Wuhan City, Hubei Province, China

    • Mag-email sa Amin

      qiao@hvtest.cc

    • Tawagan Kami

      +86-15871365102